Chart of Signal Loss per 100ft Cable Modems and Wiring Issues
Links:
home
·
search
·
speed test
·
login
·
more
·
Search for:
in
all FAQs
All FAQs
»
Cable Modems and Wiring Issues
»
2. CATV Wiring
»
3408
Chart of Signal Loss per 100ft
(#
3408
)
Coax Cable Signal (Attenuation) Loss per 100ft
Loss at
RG-59
RG-6
RG-11
1MHz
0.4dB
0.2dB
0.2dB
10MHz
1.4dB
0.6dB
0.4dB
50MHz
3.3dB
1.4dB
1.0dB
100MHz
4.9dB
2.0dB
1.6dB
200MHz
7.3dB
2.8dB
2.3dB
400MHz
11.2dB
4.3dB
3.5dB
700MHz
16.9dB
5.6dB
4.7dB
900MHz
20.1dB
6.0dB
5.4dB
1000MHZ
21.5dB
6.1dB
5.6dB
feedback form
feedback form
Any feedback you provide (corrections, updates or suggestions) are sent to the owner of this FAQ
and anyone else involved in writing or editing this item.
by Raydr
last modified: 2002-12-15 10:15:35
Thank you for using lo-fi dslreports.com -
report bugs
© 99-2009 silver matrix LLC