Coax Cable Signal (Attenuation) Loss per 100ft
Loss at
RG-59
RG-6
RG-11
1MHz
0.4dB
0.2dB
0.2dB
10MHz
1.4dB
0.6dB
0.4dB
50MHz
3.3dB
1.4dB
1.0dB
100MHz
4.9dB
2.0dB
1.6dB
200MHz
7.3dB
2.8dB
2.3dB
400MHz
11.2dB
4.3dB
3.5dB
700MHz
16.9dB
5.6dB
4.7dB
900MHz
20.1dB
6.0dB
5.4dB
1000MHZ
21.5dB
6.1dB
5.6dB